Installation

(for qualified installers only)

19

© Travis Industries

4141208

100-01404

Gas Line Location

NOTE FOR RIGID PIPE: When using rigid pipe, you may wish to disconnect the shutoff valve from the fireplace
and route the pipe through the fireplace wall. First, disconnect the gas line from the shutoff valve (see step 1
below). Then remove the shutoff valve from the cover plate (4 screws outside fireplace). The pipe may be routed
through the cover plate and the shutoff valve and gas line may be re-attached inside the fireplace.

Converting Gas Line to the Left Side

1. Disconnect the gas line from the shutoff valve (3/4” wrench). Gas line is located inside the fireplace on the

right side.

2. Remove the screw that holds the shutoff valve plate in place (1/4” nutdriver). Remove the shutoff valve plate.

3. Remove the cover plate from the left side of the fireplace (it is held in place in the same fashion as the shutoff

valve plate). Attach it to the right side of the fireplace.

4. Attach the shutoff valve plate to the left side of the fireplace. Route the gas line to the left side and re-attach

the gas line to the shutoff valve. Make sure to leak test the entire gas line.

The gas inlet is located 3.375" (86mm)

above the base of the fireplace.

7"
178mm

9"
229mm

Right Side Gas Inlet (Stock)

Left Side Gas Inlet (requires addtional flex connector)

6.625"

169mm

The gas inlet is located 3.375" (86mm)

above the base of the fireplace.