Installation

(for qualified installers only)

11

Travis Industries

9 3 5 0 8 1 0 7

1 0 0 2 0 1

Approved Venting Configurations with a Horizontal Termination

¥

If using a Snorkel Termination (14Ó or 36Ó) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).

¥

The termination must fall within the shaded area shown in the chart. Use restrictor position #1.

Natural Gas (NG)
Installations

Propane (LP)
Installations

5 feet

0 feet

10' (max)

0 feet

5 feet

0 feet

0 feet

NOTE:

Horizontal sections

require a 1/4" rise every

12" of travel.

12 feet

(max)

NOTE:

A minimum 2 foot rise is required

directly off of the stove.

12 feet (max)

5 feet

10' (max)

5 feet

Use Restrictor Position # 1

(all shaded areas)

NOTE:

If terminating into this area

when installed at an altitude

above 2,000 feet, the main

burner orifice will need to be

de-rated as follows:

LP

2,000' to 4,000' #49

4,000' to 8,000' #50

8,000' or higher #51

5 feet

0 feet

11' (max)

0 feet

5 feet

0 feet

0 feet

NOTE:

Horizontal sections

require a 1/4" rise every

12" of travel.

NOTE:

A minimum 3 foot rise is required

directly off of the stove.

12 feet (max)

11' (max)

5 feet

Use Restrictor Position # 1

(all shaded areas)

NOTE:

If terminating into this area

when installed at an altitude

above 2,000 feet, the main

burner orifice will need to be

de-rated as follows:

NG

2,000' to 8,000' #31

8,000' or higher #32

12 feet

(max)

5 feet