Finalizing the installation, Installation – Avalon Firestyles Salish-1999 to 2000 User Manual

Page 14

Advertising
background image

14

Installation

(for qualified installers only)

Travis Industries

9 3 5 0 8 1 0 7

1 0 0 2 0 1

Finalizing the Installation

!

Turn the gas control valve to ÒOFFÓ prior to conducting any service.

1

Open the door (see page 16).

2

Install the log set and coals (see page 17).

!

We recommend you purge the gas line at this time (with the door open). This allows gas to be
detected once it enters the firebox, ensuring gas does not build up.

3

Close and secure the door (see page 16).

4

Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start
the main burner. Leak test all gas joints again.

5

Check the pilot flame to make sure it looks like the illustration below. Adjust the pilot flame if
necessary.

PILOT ADJ

T

O

L

PI

ON

OFF

Standard
Screwdriver

Micro (1/16Ó)
Standard
Screwdriver

Cover Screw

Cover Screw Gasket

Needle Valve

Thermopile

Pilot Hood

3/8Ó

Thermocouple

The pilot flame should touch
only the top 3/8Ó of the
thermopile. Adjust the pilot up
or down as necessary.

To adjust the pilot flame, remove the cover screw and gasket and turn the needle
valve (NOTE: if the needle valve is totally unscrewed, gas will come out of this port).
Clockwise lowers the flame while counter-clockwise raises it. Replace the cover
screw and gasket