Safety label, Minimum clearances to combustibles – Avalon Firestyles Salish-1999 to 2000 User Manual

Page 26

Advertising
background image

26

Safety Label

Travis Industries

9 3 5 0 8 1 0 7

1 0 0 2 0 1

The listing label is shown below for your records. It can be found on the back panel.

Salish DVL Stove

Listed Gas-Fired

Vented Fireplace Heater

Tested and certified by OMNI-Test Laboratories, Inc. to the combustion performance and construction requirements of ANSI Z21.88/CSA 2.33-1998,
applicable sections of UL 307b and CAN/CGA 2.17-M91.
The DVL FS is equipped from the factory only for use with Natural Gas. For conversion to LP (Propane) use kit supplied by the manufacturer. This
appliance must be installed in accordance with all local codes, if any; if not, in USA follow ANSI Z223.1-1992 and NFPA 54(88), in Canada CAN/CGA B-
149. Installation in Manufactured or Mobile Homes must conform with: In USA, Manufactured Home Construction and Safety Standard, Title 24 CFR,
Part 3280; In Canada, CSA Z240.4 and Gas-Equipped Recreational Vehicles and Mobile Housing. This appliance is only for use with the type of gas
indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local
codes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless a certified kit supplied by the manufacturer
is used. See owner’s manual for information on making these changes. This appliance uses a millivolt-type control system consisting of a gas con-
trol valve/regulator, a standing pilot burner assembly, a thermopile, a thermocouple, a piezo ignitor, and the ON/OFF switch. THIS UNIT DOES NOT
REQUIRE 110 VOLT POWER TO OPERATE. All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from
outside the living-area structure.

This appliance is a Vented Gas Fireplace Heater. Not for use with Solid Fuel.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information
manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide
(CO) poisoning and possible death.
Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annually by
a qualified service person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present.
The control compartment, the burner compartment and all circulating air passageways of the appliance must be kept clean and clear at all times.
This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation instructions.
This vented gas fireplace heater is not for use with air filters.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or clothing ignition.
Young children should be carefully supervised at all times when they are in the same room as the appliance.
CAUTION:Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.
CAUTION:Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or
qualified service person.
Use Simpson DURA-VENT direct vent system (Model GS) to vent this appliance to the exterior.

10850 117th Pl. N.E. Kirkland, WA 98033

Minimum Clearances to Combustibles

Unit to Sidewall ..................... 10” / 255mm

Alcove Min. Height ................

60” / 1520mm

Unit to Backwall .................... 4” / 100mm

Alcove Max. Depth.................

48” / 1220mm

Unit to Cornerwall ................. 4” / 100mm

Alcove Min Width................... 47-3/8” / 1205mm

Front of Unit........................... 36” / 910mm

L.P.

N.G.

L.P.

N.G.

Input Rate on “HI” (BTU/Hr) . . . . . . . 43,000

43,000

Minimum Inlet Pressure (inches W.C.) . . . . . . . . 11.5” 5.5”

Input Rate on “LO” (BTU/Hr) . . . . . . 23,000

23,000

Maximum Inlet Pressure (inches W.C.) . . . . . . . .

13”

7”

Maximum Output (BTU/Hr) . . . . . . . 33,970

33,540

Manifold Pressure on “HI” (inches W.C.) . . . . . .

11”

3.5”

Main Burner Orifice (DMS) . . . . . . . .

#48

.125”

Manifold Pressure on “LO” (inches W.C.) . . . . .

2.7”

1”

This appliance is equipped for installation in Canada up to 4500 ft. (1370 m) with certain vent configurations. See
owner’s manual for restrictions on vent configurations.

In USA, this appliance is equipped for installation from 0-2000 ft. (0-610 m). For altitudes above 2,000 feet, the vent
configuration, orifice, or combination of both may need to be changed. See owner’s manual for information on making
these changes.

FAN TYPE VENTED CIRCULATOR

Steady State Efficiency . . . . Up to 78% (blowers on)

Blower Electrical Rating: 115V., 1.5 Amps, 60 Hz, 150 Watts

Output Capacity Rating. . . . Up to 33,970 (blowers on)

Manufacture

1999

Jan.

Apr.

Jul.

Oct.

Date:

2000

Feb.

May

Aug.

Nov.

2001

Mar.

Jun.

Sep.

Dec.

IGN 9-0213

TM

Report No. 028-S-22-05 February, 1999