Optional Equipment

29

Travis Industries

9 3 5 0 8 1 0 7

1 0 0 2 0 1

3

Follow the directions below to remove the natural gas orifice. Apply thread sealant to the LP orifice
(#48 - it has "48" stamped on it) and tighten in place with a 1/2" open end wrench. Slide the
adjustable shutter back in place over the orifice.

Loosen the air shutter
control (see page 15).

1/2" Wrench

Use a 1/2Ó open end wrench
to unscrew the orifice.

Orifice

Air
Control
Shutter

1/8

48

The new LP orifice has
Ò48Ó stamped on it.

The NG orifice
has Ò1/8Ó (0.125Ó)
stamped on it.

Apply thread
sealant to the
new orifice
prior to
installation.

a

b

c

d

Rotate the air control shutter
away from the orifice.

NOTE:
Screw the LP orifice in so the
orifice shoulder protrudes
5/16Ó (indicating full insertion).

5/16Ó

4

Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice. The
propane conversion kit includes a .016Ó (labeled LP 16) or .011Ó (labeled LP 11) pilot orifice. The
.016Ó orifice is preferred because it allows for greater pilot adjustment.

Remove the pilot

hood assembly by

unscrewing the two

attachment screws.

Pilot Orifice

LP (Propane) Orifices

Pull the pilot orifice

retainer and pilot orifice

upwards to remove.

Pilot Orifice
Retainer

Phillips
Screwdriver

Pilot Hood

Assembly

1

1

P

L

Orifice Identification:

1

6

P

L

(preferred)

NG (Natural Gas) Orifices

1

8

N

2

1

N

(preferred)