BUG-O Systems SE-4PTD User Manual

Page 19

Advertising
background image

19

DATA ENTRY required for Programming

To Program a complete new shape (press ‘A’)

Count the number of segments or operations and enter the total.

For each segment, enter:

Type:

Select form 1 through 8

Quadrant:

1, 2, 3 or 4; refer to chart

Size:

one or more dimensions per segment as described below

100 per inch or 10 per mm (depending on machine version); or for
time, 100 per second of delay.
(e.g. 150 = 1.5”, or for metric 375 = 37.5 mm)

Detailed description of Types

Type 1.

Clockwise, 90° arc segments.
Quadrant determined by which quarter of a full circle makes the arc. (See chart)
Dimensions required: Radius only.

Type 2.

Counterclockwise, 90° arc segments
Quadrant determined by which quarter of a full circle makes the arc. (See chart)
Dimensions required: Radius only.

Type 3.

Lines along X or Y axis.
Quadrant determined by direction of movement. (See chart)
(East: 1, North: 2, West: 3, South: 4).
Dimensions required: Length only.

Type 4.

Angled straight line.
Quadrant determined by direction of movement. (See chart)
(NE: 1, NW: 2, SW: 3, SE: 4).
Dimensions required: (1) X- dimension; movement along X axis

(2) Y- dimension; movement along Y axis

Advertising