BUG-O Systems SE-4PTD User Manual

Page 21

Advertising
background image

21

Type 8.
Counterclockwise arc, must be less than 180°.
Quadrant determined by direction of end point of arc relative to the start point. (See Chart)
Dimensions required:

(1) X-dimension: offset along X-axis from Start to end point.
(2) Y-dimension: offset along Y-axis from start to end point.
(3) Radius of arc.

AUXILIARY MODES: Type 6, Quadrant 3

These are additional controls to independently turn the two internal Solid State Relay outputs ON and
OFF, and to switch the machine into Rapid Traverse Mode or Set speed.

The machine is shipped with OUTPUT (1) wired to the external relay or solenoid connector. By
default, this output turns ON when the Start button is pressed to run a shape, and turns OFF at the
end. The output is taken from screws (3) and (4) on the 4-terminal strip, on the controller inside the
machine.

ONLY OUTPUT (1) IS NORMALLY USED.

OUTPUT (2) is present at screws (1) and (2) on the controller, but not wired. By default the output is
OFF when a shape is started, until turned ON by command Type 5, Quad 1. Both the SEO-4470
Plasma Cutting Kit and the SEO-4490 Oxyfuel Cutting kit use only output (1). Subsequently while
running, the Type 5 ON and OFF command turns both outputs On and Off together, and both Off at
the end.

When programming Type 6 Quad 3, a Mode number is required to be entered. The eight auxiliary
modes, numbered 0 through 7, allow the setting of a mode with any combination of outputs On or
Off, and choice of set speed by the speed knob, or maximum speed regardless of setting. The
combinations are listed in the table below:

Mode No

Output 1

Output 2

Speed

0

Off

Off

Set

1

Off

On

Set

2

Off

Off

HI

3

Off

On

HI

4

On

Off

Set

5

On

On

Set

6

On

Off

HI

7

On

On

HI

Advertising