BUG-O Systems SE-4PTD User Manual

Page 8

Advertising
background image

8

OPERATION
To make a cut:

1. Set up the SE-4PTD with pipe in position and power up.

2. Program the desired cut. (Refer to the instructions under programming.)

3. Push the red Stop button and use the joystick to manually move to the starting point.

4. Push the Reset button to fix the starting point here.

5. For oxy-fuel, turn on and ignite the pre-heat gases, and wait until is hot enough to start the
cut. Push the Start button; the solenoid for cutting oxygen or plasma trigger is turned on
and the machine starts the cut (after the delay which has been set for plasma).

NOTE: TYPE 4, MITRE

If a cutback dimension has been entered, the SE-4PTD will make one cut, shut off

the gas or arc, back up the given distance, and rotate the 180°. The machine will

pause here until Start button is pressed again, and then repeat the same cut but

rotated 180° from the first.

To make a dry run without cutting:

1. Push Stop button and hold down.

2. Push Start button and hold down.

3. Release Stop button (quickly, after no. 2 above).

4. Release Start button.

The machine will move along the programmed cut without turning on the contacts for plasma,
or the cutting solenoid.

Advertising