Torque (lbfx ft) = 5250 Shutoff Power (hp)

r/min

Torque required by the pump at any other speed

during start-up can be determined from the curve.

Note that the driver manufacturer usually bases 100

percent torque on the design power of the driver and

consequently the speed-torque curves should be

plotted in torque units (e.g. Nm) instead of

percentage torque to avoid confusion.

3.4.3

MAXIMUM WORKING PRESSURES -bar
(psi).

Above ambient temperature these maximum

pressures shall be derated.

Do not conduct a hydro test on the

namplete pump set without the specific approval of

Flowserve. While the duty requirement will have been

covered, auxiliary items, flange drillings and suction

pressure limits may impose a reduced static and

dynamic pressure rating compared to that of the

pump casting rating itself.

Note: all flanges are ANSI 125 (Cast Iron or Ductile

Iron-flat faced) or ANSI 150 (Stainless-raised face)

unless otherwise stated. All flange facings on the

casings are 250 rms – circular finish

CONSTRUCTION

CAST IRON AND C.I.S.S. FITTED

STAINLESS STEEL

316,317L, WORTHITE, ETC.

TEMPERATURE

°C (

°F)

UP TO 12”

DISCHARGE

14 TO 16”

DISCHARGE

UP TO 16”

DISCHARGE

-30 to 38 (-20 to100)

10.3 (150)

10.3 (150)

13.8 (200)

65 (150)

10.3 (150)

9.7 (140)

13.8 (200)

95 (200)

10.3 (150)

9.3 (135)

13.4 (195)

120 (250)

10.3 (150)

9.0 (130)

12.6 (185)

150 (300)

Consult factory for applications in this range. Cast
iron not recommended due to thermal shock risks.

12.1 (175)

175 (350)

11.0 (160)