5.9 Hydraulic, mechanical and electrical

duty

This product has been supplied to meet the

performance specifications of your purchase order,

however it is understood that during the life of the

product these may change. The following notes may

help the user decide how to evaluate the implications

of any change. If in doubt contact your nearest

Flowserve office.

5.9.1

Specific gravity (SG)

Pump capacity and total head in metres (feet) do not

change with SG, however pressure displayed on a

pressure gauge is directly proportional to SG. Power

absorbed is also directly proportional to SG. It is

therefore important to check that any change in SG

will not overload the pump driver or over-pressurize

the pump.

5.9.2

Viscosity

For a given flow rate the total head reduces with

increased viscosity and increases with reduced

viscosity. Also for a given flow rate the power

absorbed increases with increased viscosity, and

reduces with reduced viscosity. It is important that

checks are made with your nearest Flowserve office

if changes in viscosity are planned.

5.9.3

Pump speed

Changing pump speed effects flow, total head, power

absorbed, NPSH

R

, noise and vibration. Flow varies

in direct proportion to pump speed, head varies as

speed ratio squared and power varies as speed ratio

cubed. The new duty, however, will also be

dependent on the system curve. If increasing the

speed, it is important therefore to ensure the

maximum pump working pressure is not exceeded,

the driver is not overloaded, NPSH

A

> NPSH

R

, and

that noise and vibration are within local requirements

and regulations.

5.9.4

Net positive suction head (NPSH

A

)

NPSH available (NPSH

A

) is a measure of the head

available in the pumped liquid, above its vapour

pressure, at the pump suction branch.

NPSH required (NPSH

R

) is a measure of the head

required in the pumped liquid, above its vapour

pressure, to prevent the pump from cavitating. It is

important that NPSHA > NPSH

R

. The margin

between NPSH

A

> NPSH

R

should be as large as

possible.

If any change in NPSH

A

is proposed, ensure these

margins are not significantly eroded. Refer to the

pump performance curve to determine exact

requirements particularly if flow has changed. If in

doubt please consult your nearest Flowserve office

for advice and details of the minimum allowable

margin for your application.

5.9.5

Pumped flow

Flow must not fall outside the minimum and

maximum continuous safe flow shown on the pump

performance curve and/or data sheet.

6

MAINTENANCE

6.1 General

It is the plant operator's responsibility to ensure

that all maintenance, inspection and assembly work

is carried out by authorized and qualified personnel

who have adequately familiarized themselves with

the subject matter by studying this manual in detail.

(See also section 1.6.2.)

Any work on the machine must be performed when it

is at a standstill. It is imperative that the procedure

for shutting down the machine is followed, as

described in section 5.8.

On completion of work all guards and safety devices

must be re-installed and made operative again.

Before restarting the machine, the relevant

instructions listed in section 5,

Commissioning, start

up, operation and shut down

must be observed.

Oil and grease leaks may make the ground

slippery. Machine maintenance must always

begin and finish by cleaning the ground and the

exterior of the machine.

If platforms, stairs and guard rails are required for

maintenance, they must be placed for easy access to

areas where maintenance and inspection are to be

carried out. The positioning of these accessories

must not limit access or hinder the lifting of the part to

be serviced.

When air or compressed inert gas is used in the

maintenance process, the operator and anyone in the

vicinity must be careful and have the appropriate

protection.

Do not spray air or compressed inert gas on skin.

Do not direct an air or gas jet towards other people.

Never use air or compressed inert gas to clean

clothes.