Flowserve MARK 3 GROUP 4 User Manual

Page 40

Advertising
background image

MARK 3 GROUP 4 USER INSTRUCTIONS ENGLISH 71569286 08-12

Page 40 of

48

flowserve.com

®

b) Set the impeller clearance by loosening the set

screws [6577] and rotating the thrust bearing

housing [3240] to obtain the clearance. Turn the

thrust bearing housing counter-clockwise until

the impeller comes into light rubbing contact with

the casing [1112]. Rotating the shaft at the same

time will accurately determine this zero setting.

Now, rotate the thrust bearing housing clockwise

to get the proper clearance. Rotating the thrust

bearing housing the width of one of the indicator

patterns cast into the thrust bearing housing

moves the impeller axially 0.1 mm (0.004 in).

(Figure 2).

It is recommended that two

people install an impeller. The weight of an impeller

greatly increases the chance of thread damage and

subsequent lock-up concerns.

c) Determine how far to rotate the thrust bearing

housing by dividing the desired impeller

clearance by 0.10 (one indicator pattern).

Tightening the set screws [6577] will cause the

impeller to move 0.005 mm (0.002 in) closer to

the casing because of the internal looseness in

the thrust bearing housing threads. This must be

considered when setting the impeller clearance.

Rotate the thrust bearing housing clockwise the

required amount to get the desired clearance to

the casing. Lastly, tighten the set screws [6577]

to lock the thrust bearing housing in place.

Advertising