Integer
Register

Attribute Description

Notes

40105

RW

Variable number of output No. 10 to be
displayed on Local display.

Range -1 to 1023. Writing a value in the
specified range will cause the device to
display the output from that variable on the
LCD display; -1 disables.

30106

RO

Hardware status register.

Bit field Bit Meaning

0 Watch dog reset occurred

1 SRAM R/W failure

2 EPROM checksum error

3 NVRAM R/W failure

4 Thermocouple alarm

5 A-D converter No. 1 failure

6 A-D converter No. 2 failure

7 PII failure

8 Vcc supply failure

9 -15V supply failure

10 +.33V reference failure

11 +15V supply failure

12 D-A converter No. 1 failure

13 +10V reference failure

14 NVRAM checksum error

30107

RO

Sensor status register.

Bit field Bit Meaning

0 = P

1

sensor error

1 = P

2

sensor error

2 = Top actuator sensor error

3 = Bottom actuator sensor error

4 = Thermocouple sensor error

5 = Ambient temperature sensor error

6 = Position sensor error

40108

RW

Loss of supply pressure hold time.

Range 0 to 9999. Seconds

30109

RO

Process Variable unit type

Range 0 to 70

30110 RO

Override

status

40111

RW

Remote command refresh rate

Range 0 to 30000 sec

40112

RW

Enable mask for alarm source bit fields

Range 0 to 255, See register 30028, use
BCD

40113

RW

Pressure transducer type

0 = voltage

1 = current

40114

RW

Var number for dP valve input to be used
in flow calculation.

-1 to 1023

StarPac II User Interface Manual