ELECTRICAL CONNECTION INSTRUCTIONS

7.2

Injector Sizes for Gas Cooktops

MODEL

BURNER

FED

SEMI-RAPID

1.18

6.0

0.65

5.4

RAPID

1.6

12

0.92

11.0

WOK x 2

1.8

14.5

0.95

12.0

FE90

AUXILIARY

0.9

4.0

0.50

3.2

SEMI-RAPID

1.18

6.0

0.65

5.4

RAPID

1.6

12

0.92

11.0

WOK

1.8

14.5

0.95

12.0

FISH BURNER

1.4

9.5

0.85

10.0

NATURAL GAS

LPG

INJECTOR DIAMETER

MJ/h

INJECTOR DIAMETER

MJ/h

mm

mm

7.3

Conversion from Natural Gas to ULPG

THE FOLLOWING MUST BE CARRIED OUT BY AN AUTHORISED PERSON

General Information
The Hob is supplied pre-adjusted for Natural Gas.
1. The injectors required for adapting this Appliance to ULPG are supplied in the Conversion Kit P/N 51587 for FED and P/N 51586.
2. When the appliance has been converted to ULPG tick the box on the injector information label P/N 51589 for FED P/N 51588 for FE90.
3. Change the Black Natural Gas labels to the Red ULPG labels.

Conversion
1. Remove the Pan Supports, Burner Caps, Burner Ring/dress Rings.
2. Remove the fitted injectors one by one and replace with the ULPG injector sized as the label 51589 (FED) or 51588 (FE90) attached to

the appliance and also in the Users Manual.

3. Fit the Test Point Adaptor at the Gas Inlet.
4. Replace all the Burner parts ensuring that they are correctly keyed to the mating part.
5. After fully leak testing and working on each burner in turn, remove the control knob and light the burner and then adjust the minimum

flame via the adjustment screw in the centre of the Gas Cock shaft. With the gas cock set in the low flame position, turn the adjustment
screw clockwise to reduce the flow to the required level. Two burners should be full on while adjusting a burner.

6. Replace the Control Knobs and Pan Supports.