WARNING

TO AVOID MAINS BORNE INTERFERENCE, THIS APPLIANCE MUST BE INSTALLED

INDIVIDUALLY ON A SEPARATE AND DISTINCT FINAL SUBCIRCUIT

ELECTRICAL CONNECTION INSTRUCTIONS

8.

ELECTRICAL CONNECTION INSTRUCTIONS AND WIRING DIAGRAMS

8.1

Wiring Rules and Warnings

WARNING: All aspects of the installation must conform with the requirements of the Standards Australia (within

Australia) Wiring Rules as well as your local electrical and building codes and regulations and any
other applicable requirements and conditions of your Local Power Supply Authority.

A licensed electrician must perform the electrical work when installing this appliance. The supply
cable and fuse rating must be suitable for the appliance.

WARNING: To avoid mains borne interference, this appliance must be installed individually on a separate and distinct

final sub-circuit.

NOTE: To the Electrician – please ensure sufficient supply cable is provided to allow the appliance to be removed from

the cavity should any servicing be necessary. This will also allow easy connection of the supply.

8.2

Voltage Supply Connection

To connect the electrical supply:-

1. Ensure the supply cable and fuse rating are suitable for the appliance (see Electrical Loads).

2. For models not fitted with a flexible lead and plug, remove the cover plate by undoing the screws.

3. Fit a suitable entry bush to the conduit entry bracket and feed the fixed wiring through.

4. Connect the wiring to the terminal block using the screw connections provided. Ensure the wires are properly

secured to prevent any high resistance electrical connection.

For the FED model, the supply can be single or 2 phase. For 2 phase connection the link between A1 and A2
must be removed.

5. Replace the cover plate and secure in position using the screws making certain that all wiring is clear of any

metal work and the screws.