Installation, Wiring, Removing and installing the glass doors – Montigo M40DV CL CR User Manual

Page 14: Gas control and pilot wiring, Removing the louvres and side panels, Removing the doors, Door installation

Advertising
background image

P/N XG0206

Page 14

M40DV-CR/CL Corner Gas Fireplace

Installation

Wiring

Gas Control and Pilot Wiring

Figure 21. Wiring for the M40DV-CR/CL-I with Honeywell gas control

and pilot.

M40DV-CR/CL-I

Removing and Installing the

Glass Doors

Removing the Louvres and Side Panels

Rotate the upper end louvre assembly approximately 110° (as shown
in figure 22a, step ). Pull the assembly towards you to remove it
from the fireplace.
Repeat this for the lower end louvre assembly.

Remove the louvre assemblies (upper and lower) from one side of the
fireplace. Grasp the assembly underneath one of the louvres and up
slightly and pull outwards, as shown in figure 22a.
Remove the side panel by sliding it out and away from the back of the
fireplace. Refer to figure 22b.

Removing the Doors

Figure 22a. Removing the louvre assemblies.

Figure 22b. Removing the side panel.

To remove the inner doors, simply unscrew the eight (8) machine
screws on the top and bottom of the door.

(See figure 22c).

Door Installation

To re-install the doors, align the door with the screw holes and
re-fasten with all eight machine screws. Ensure that a good seal is
maintained.
Re-install the side panels and louvre assemblies by reversing the
above steps.

Figure 22c. Removing the door.

Figure 20c. When using a tile surround, do not tile over the outside

Honeywell (Q3450)
Pilot Assembly

Pilot Electrical
Harness Connector

Honeywell Gas
Control (SV9501M)

Gas Control
Connector

Junction Box

115VAC
24VAC

40 VA
Transformer

Black

White

Green

Gnd Screw