Page 20

M40DV-CR/CL Corner Gas Fireplace

Maintenance

Troubleshooting

If your fireplace still does not operate correctly, consult your dealer or
the manufacturer.
All service and repairs should be performed by a qualified

agency.
All spare parts, optional fans (see optional fan instruction guide), and
optional trim finishes are available from Canadian Heating Products
Inc. or your local dealer.

M40DV-CR/CL-I

Troubleshooting

The following is a troubleshooting chart of possible problems:

PROBLEM

CORRECTIVE ACTION

Noisy Pilot Flame

Locate pilot adjustment screw on the
front of the gas control valve. Flame
is decreased by turning adjustment
screw clockwise.

Pilot won’t ignite

Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram

figure

17.

Main burner will

1. Check wiring

(see figure 17)

not light

2. Check wall switch for proper con-
nection.

3. Check pilot burner. If extinguished:

a. Allow fireplace to cool, then try to
relight.

b. If condition persists, call a qualified
service person.

M40DV-CR/CL

H-Series DF-A

Troubleshooting

Follow this information to reset the SIT System:
1. Locate the lead to the battery backup, (remove)
(Refer to schematic, below)

2. Locate the AC/DC wall transformer, (Unplug connector)
(Refer to schematic, below)

f your fireplace still does not operate correctly, consult your dealer or
the manufacturer.