M40DV-CR/CL Corner Gas Fireplace

with Proflame SIT Electronic Ignition

Operation - Model M40DV-CR/CL-F

with American Flame Electronic Ignition

For Your Safety - READ BEFORE LIGHTING:

WARNING:

If you do not follow these instructions exactly, a fire or explosion may

result causing property damage, personal injury or loss of life.

To Turn Off Gas To Appliance:

Lighting Instructions:

If you cannot reach your gas supplier, call the

Fire Department.

C. Use only your hand to push in or turn the gas

control knob. Never use tools. If the knob will

not push in or turn by hand, don't try to repair it,

call a qualified service technician. Force or at-

tempt to repair may result in a fire or explosion.

D. Do not use this appliance if any part has been

under water. Immediately call a qualified serv-

ice technician to inspect the appliance and to

replace any part of the control system, and any

gas control which has been under water.

A. This appliance is equipped with an ignition sys-

tem that lights the pilot burner automatically.

Do

not attempt to light the pilot by hand.

B. BEFORE LIGHTING smell all around the appli-

ance area for gas. Be sure to smell next to the

floor because some gas is heavier than air and

will settle on the floor.

What To Do If You Smell Gas:

Do not try to light any appliance.

Do not touch any electrical switch; do not use

any phone in your building.

Immediately call your gas supplier from a

neighbour's phone. Follow the gas supplier's

instructions.

1. Turn off remote switch.

2. Flip down the lower trims.

3. Turn the incoming gas control valve to "Off".

4. Flip UP the lower trims.

1. STOP! Read the safety information above on

this label.

2. Flip down the lower trims.

3. Turn Incoming gas valve to the ON" position.
4. Wait 5 minutes to clear out any gas. If you smell

gas,

STOP! Follow "B" in the safety information

above on this label. If you don't smell gas, go to

the next step.

5. Turn wall switch "ON".

6. If the Fireplace does not light, the System will cy-

cle through two trials, (one minute audible click-

ing, thirty seconds of silence, and then another

one minute of audible clicking). If the system

locks out due to inadequate gas flow, refer to

"Troubleshooting", Page 20.

7. After completion of the information in the Trou-

bleshooting section, Repeat step 5.

8. If the system will not function correctly, follow the

instructions "To Turn Off Gas To Appliance" and

call your service technician or gas supplier.

EV1 (Pilot

burner)

EV2 (Main

burner)

Pilot Adjust Screw

Lockout Reset Key

Diagnostic Terminal

Power

Command (Wall

switch)

Pilot Sensor

Igniter

Ground

EV1 (Pilot burner)

EV2 (Main burner)

Gas "Out"

Gas "In"

Incoming Gas

Line, Shut-off

Valve

To fireplace

Main burner

M40DV-CR/CL-F

with Proflame SIT Electronic Ignition