Chapter 3: Featuring Configuration

– Web UI

Featuring Configuration

– Web UI

NGSME16T2H User Manual | 62

RMON History Configuration

Configure RMON History table on this page. The entry index key is ID

Delete

Check to delete the entry. It will be deleted during the next save.

ID

Indicates the index of the entry. The range is from 1 to 65535.

Data Source

Indicates the port ID which wants to be monitored. If in stacking switch, the value

must add 1000*(switch ID-1), for example, if the port is switch 3 port 5, the value is

2005.

Interval

Indicates the interval in seconds for sampling the history statistics data. The range is

from 1 to 3600, default value is 1800 seconds.

Buckets

Indicates the maximum data entries associated this History control entry stored in

RMON. The range is from 1 to 3600, default value is 50.

Buckets Granted

The number of data shall be saved in the RMON.

Buttons

Add new entry: Click to add a new community entry.

Save: Click to save changes.

Reset: Click to undo any changes made locally and revert to previously saved

values.