Alarm Application

The alarms menu is where alarm connections are
configured.

Alarm Switch

Designate when the alarm will be

active; Off, On, or By Schedule.

Alarm Type

Designate if the alarm is normally

open or normally closed.

NOH

– NO stands for Normally Open.

NC/L

– NC stands for Normally Closed.

Example:

A door sticker consists of two contacts that are connected when under

normal conditions. This type of input would be a NC/L or normally closed alarm.
The alarm will trigger when the two contacts are no longer connected, such as an
abnormal condition when the door is opened.

Alarm Output

Choose high or low.

Trigger Action

Specify which actions the camera should take when motion is detected.

Send Alarm Message by FTP / E-mail

Select to send an alarm message to a

configured FTP and/or e-mail address when motion is detected. When sending to
email, the alarm notification is text only. When sending to FRP, the alarm
notification will upload a text file to the FRP location.

Upload Images by FTP

Select to assign an FTP site and configure various

parameters as shown in the figure below. When motion is detected, event
images will be uploaded to the appointed FRP site.

Upload Image by E-mail

Select to assign an e-mail address and configure

various parameters as shown in the figure below. When motion is detected,
event images will be sent to the appropriate e-mail address.

Make sure SMTP or FTP configuration has been completed. See the Mail
and FTP sections for more information.

File Name

Enter a file name in t

he box, ex. Image.jpg. The uploaded image’s

file name format can be set in this section. Select the one that meets your
requirements.

Consult the documentation to the sensor input device to determine which of these to use.