Remko heat pump manager – REMKO Multi-talent Plus User Manual

Page 50

Advertising
background image

REMKO Heat Pump Manager

B

A

AB

F9

F14

A

B

AB

F6

F8

F12

A

B

AB

l/h

Tmax

V

V

F17

F11

II

0

I

3)

A9

A3

A6

A12

A3

A10

A8

M

2)

1)

F5

A2

A4/A5

A10

4)

Designation

Value range

Programming

Output/level

00 – 9950 kW

WE 1 level 1 = 50

WE 3 level 1 = 1

continue with key next to "End"
MF 1 function

0 0 - 3 7

37

T - MF 1 target

- 2 0 °C - 9 0 °C

( ---- )

MF 1 Hyst

2 K - 1 0 K

( ---- )

MF 1 Hyst Off

2 K - 1 0 K

( ---- )

MF 2 function

0 0 - 3 6

18

T - MF 2 target

- 2 0 °C - 9 0 °C

( ---- )

MF 2 Hyst

2 K - 1 0 K

( ---- )

MF 2 Hyst Off

2 K - 1 0 K

( ---- )

MF 3 function

0 0 - 3 6

3 4

T - MF 3 target

- 2 0 °C - 9 0 °C

( ---- )

MF 3 Hyst

2 K - 1 0 K

( ---- )

MF 3 Hyst Off

2 K - 1 0 K

( ---- )

MF 4 function

0 0 - 3 6

2 3

T - MF 4 target

- 2 0 °C - 9 0 °C

( ---- )

MF 4 Hyst

2 K - 1 0 K

5.0K

MF 4 Hyst Off

2 K - 1 0 K

2.0 K

F15 function

0 0 - 0 9

09

E 1 function

0 0 - 0 3

0 2

E 2 function

0 0 - 0 3

0 3

Sensor

1k/5k sensors

5k sensors

Designation

Value range

Programming

BUS code BM

Off, 00-15

Off

Language

D/GB/F/NL/E/I

D (German)

Terminal address

On / Off

On

Time

0-24

Set time

Date

Year, month, day

Set date

BUS code 1

00-15

01

BUS code 2

00-15

02

System selection

---/01-12

07

Regulator type

00-06

06

WE 1 type

00-09

07

WE BUS

00-05

05

Gradient

On / Off

Off

WE 2 type

00-22

08

WE 2 tank

00-03

00

WE 3 type

00-09

01

WE 4 type

00-09

00

Buffer type

00-02

00

Cooling mode

Off/On

On

HC1 function

Standard,T-feed

const, swimming

pool, WW,

return

Standard

HC2 function

see HC1

Standard

Outdoor unit

Indoor unit

CMF 120/160

Heating circuit

Taps

CW inlet

Fresh water station

Cooling circuit

Hydraulic diagram for heat pump assembly WP 11

Functions: Heating or cooling, solar and hot water

monoenergetic operating mode

“System selection 7”

Notes:

1) Heating circuit circulation pump(s) not included in REMKO's scope of delivery. We recommend the use of high-efficiency circulation pumps.

2) We recommend, because of possible high temperatures - caused by the solar plant, to always connect the heating circuit via a 3-way mixer.

3) If a circulation pump is installed, it must be controlled separately.

4) The cooling must be activated via heating circuit 1 by setting T-supply cooling to the desired cooling target supply temperature.

Multi-function

Storage tank

MPS 1000

Coolant

Storage tankr

KPS 300

50

Advertising