BEFORE YOU BEGIN
Motors are shipped in FACTORY MODE without limit settings and transmitter
Id’s. Power must ONLY be connected to current window covering being
programmed. All other window coverings must be disconnected from their
respective power while programming.

FACTORY MODE

With the motor installed in window covering, connect power to the
motor (120V AC, or 12V DC or 24V DC transformer or 12V battery wand).

Initiate Programming
On the transmitter, press and hold both the UP and DOWN
simultaneously until the window covering jogs. A jog is a brief up and
down or in and out motion. In PROGRAMMING MODE, the window
covering will move only when the UP or DOWN is held (or
momentary fashion).

CT32 CORD LIFT WIREFREE LT30 ROLL UP WIREFREE ST30 SONESSE 30 ST40 SONESSE 40

QUICK PROGRAMMING GUIDE FOR THE FOLLOWING RTS MOTORS

Note - If motor is 120V AC hardwired and cannot be disconnected, please
contact an electrician prior to calling Somfy customer service for assistance.

!

ALTUS 40 ST50 SONESSE 50 ALTUS 50 ALTUS 60

While programming, window covering should not be inactive for
longer than 2 minutes or motor will exit PROGRAMMING MODE.

Connect Power To Motor

PROGRAMMING MODE

!