QUICK PROGRAMMING FOR THERMO SUNIS INDOOR WIREFREE SENSOR

Setting the (Temperature) Sensitivity (Threshold)

STEP 1: Carefully remove rear cover of the Thermo Sunis sensor

Control

Setting Panel (See Figure 4 pg. 67).

STEP 2: Slide the ON/OFF Selector Switch to the ON or position. Sun LED
Indicator will illuminate for 5 seconds and then extinguish.

STEP 3: Momentarily press the MODE BUTTON and Sun LED Indicator Light will
illuminate for approximately 15 seconds to indicate present threshold setting.

exposing

Thermo Sunis should be mounted in or near window and
exposed to incoming sunlight.

Rotating the Sun Sensitivity Selector to a FULL COUNTER CLOCKWISE
(-) position will simulate sun if no sun is present. It is not
recommended to leave the selector (threshold setting) in this position.

!

LED Indicator light will remain illuminated for approximately 15
seconds. Should the LED Indicator light extinguish prior to establishing
the light sensitivity (threshold) setting, simply press the MODE BUTTON
momentarily to reactivate LED light.

!

STEP 4: Using a small screw driver or similar device, rotate the Sun Sensitivity
Selector to the fully CLOCKWISE (+) position. LED Indicator will remain illuminated
red color (See Figure 3 pg. 67).

STEP 5: Slowly rotate the Sun Sensitivity Selector COUNTER CLOCKWISE (-)
until the LED Indicator illuminates to a green color. A green colored LED
indicates the present light value (threshold). At this (threshold) the Thermo
Sunis sensor will provide the necessary RTS command as selected with the
Function Selector Switch.

GREEN LED: INDICATES SUNLIGHT WITHIN THRESHOLD SETTING
RED LED: INDICATE SUNLIGHT BELOW THRESHOLD SETTING

63

Advertising