Teo E911 Response Server 9145 Installation Instructions

Page 50

13-280133 Rev. C

S

S

t

t

a

a

t

t

i

i

o

o

n

n

I

I

n

n

f

f

o

o

T

T

a

a

b

b

Number Dialed for Emergency – typically 911 but is programmable so that a number

such as 711 can be used for testing so that calls are not being sent to 911 operators

during turn-up. Enter 911 here

E911 Calling Number (ANI) – should be the pilot number for your organization. If for

some reason the 9145 does not recognize the calling station number, this number

will be sent to 911 operators

E911 Notify group – used to select a notify group that will receive an alert

notification when an emergency call from an unknown station occurs.

Station Number Length – a PBX will typically use 3, 4, or 5 digit dialing to place a

station to station call. Enter the number of digits required for your organization.

Callback Number – this number will be displayed at the PSAP operator’s position as

a callback number when a call comes from an unknown station.

Send Admin Alert – instructs the unit to send alert notification to the admin notify

group when a call occurs from an unknown station.