System Operation

13-280133 Rev. C

Page 59


PRI-N Status

Meaning

Description

Solid Green

Normal, OK

The PRI-N port is functioning properly.

Solid Yellow

Telco Network

Out of Service

The 9145 is receiving Remote Alarm Indication

(RAI), also known as a Yellow Alarm.

Flashing

Yellow

9145

Out of Service

The 9145 is transmitting Remote Alarm

Indication (RAI), also known as a Yellow Alarm.

Check system Active Alarms for details.

Flashing Green

Malfunctioning

PRI-N Bipolar Violations or Frame Slips have

occurred.

Flashing Red

Not Functioning

The 9145 is receiving an Alarm Indication

Signal (AIS), also known as a Blue Alarm.

Solid Red

Not Functioning

No ISDN-PRI digital signal is being detected,

Loss of Signal (LOS).

OFF

Not Functioning

Power not applied, system not functioning.


Alarm Status

Meaning

Description

OFF

Normal, OK

No alarm condition exists.

Solid Red

Alarm Active

Alarm exists.