Installing a cfp2 module – H3C Technologies H3C S12500X-AF Series Switches User Manual

Page 42

Advertising
background image

38

2.

Pivot the clasp of the module up. Holding the module, gently push the module into the slot until it

has firm contact with the slot, as shown in

Figure 38

.

{

For a QSFP+ module that uses a plastic pull latch, skip this step.

{

For an SFP+ module, press the module down so you can push the module straight into the port.

{

If you cannot hold the module by its two sides because of high module density, press the
module on its head end to push it in.

Figure 38 Installing an SFP+/SFP/QSFP+ module (S12516X-AF switch)

Installing a CFP2 module

CAUTION:

Read the following instructions before you install a CFP2 module. Failure to follow these instructions
might cause damage.

Before you install or remove a CFP2 module, remove the optical fiber (if any) from it.

To install a CFP2 module:

1.

Unpack the CFP2 module.
Do not touch the golden plating of the module.

2.

Pivot the module handle up.

3.

Correctly orient the CFP2 module and make sure the module handle is on top of the CFP2 module.
Gently push the module into the slot until it clicks into place.