H3C Technologies H3C S7500E Series Switches User Manual

Page 140

Advertising
background image

8-6

To do…

Use the command…

Remarks

Create an entry in the private

alarm table

rmon prialarm entry-number

prialarm-formula prialarm-des

sampling-interval { absolute | changeratio |

delta } rising-threshold threshold-value1

event-entry1 falling-threshold

threshold-value2 event-entry2 entrytype

{ forever | cycle cycle-period } [ owner text ]

z

A new entry cannot be created if its parameters are identical with the corresponding

parameters of an existing entry See

Table 8-1

for the parameters to be compared for

different entries.

z

The system limits the total number of each type of entries (See

Table 8-1

for the detailed

numbers). When the total number of an entry reaches the maximum number of entries that

can be created, the creation fails.

Table 8-1 Restrictions on the configuration of RMON

Entry

Parameters to be compared

Maximum number of

entries that can be

created

Event

Event description (description string), event type (log,

trap, logtrap or none) and community name

(trap-community or log-trapcommunity)

60

Alarm

Alarm variable (alarm-variable), sampling interval

(sampling-interval), sampling type (absolute or delta),

rising threshold (threshold-value1) and falling threshold

(threshold-value2)

60

Prialarm

Alarm variable formula (alarm-variable), sampling

interval (sampling-interval), sampling type (absolute,

changeratio or delta), rising threshold

(threshold-value1) and falling threshold

(threshold-value2)

50

Advertising