Verifying the configuration, Network requirements – H3C Technologies H3C WX5500E Series Access Controllers User Manual

Page 100

Advertising
background image

92

[DeviceA] mirroring-group 1 mirroring-port gigabitethernet 1/0/1 gigabitethernet 1/0/2

both

[DeviceA] mirroring-group 1 monitor-port gigabitethernet 1/0/3

# Disable the spanning tree feature on the monitor port GigabitEthernet 1/0/3.

[DeviceA] interface gigabitethernet 1/0/3

[DeviceA-GigabitEthernet1/0/3] undo stp enable

[DeviceA-GigabitEthernet1/0/3] quit

Verifying the configuration

# Display the configuration of all mirroring groups.

[DeviceA] display mirroring-group all

mirroring-group 1:

type: local

status: active

mirroring port:

GigabitEthernet1/0/1 both

GigabitEthernet1/0/2 both

mirroring CPU:

monitor port: GigabitEthernet1/0/3

After the configurations are completed, you can monitor all packets received and sent by the marketing

department and the technical department on the server.

Local port mirroring with multiple monitor ports configuration
example

Network requirements

As shown in

Figure 34

, Dept. A, Dept. B, and Dept. C are connected to Device A through ports

GigabitEthernet 1/0/1, GigabitEthernet 1/0/2, and GigabitEthernet 1/0/3, respectively. Configure

port mirroring to enable all three data monitoring devices (Server A, Server B, and Server C), to monitor

both the incoming and outgoing traffic of the three departments.

Figure 34 Network diagram

Advertising