6.4.2 Bridging the DC Inputs on the Inverter

Requirements:

☐ A negative connection cable to bridge the DC inputs on the inverter must be equipped with

two negative DC connectors.

☐ A positive connection cable to bridge the DC inputs on the inverter must be equipped with

two positive DC connectors.

Bridge the two rear DC connectors of input A with the two rear DC connectors of input B according
to the following procedure.

1. Stop the small wind turbine system and secure against restart.
2. Disconnect the miniature circuit-breaker and secure against re-connection.
3. If the ESS is plugged in, remove the ESS.
4. Remove the filler-plugs from the rear DC connectors

of both inputs on the inverter.

5. Connect the positive DC connectors of input A with

the positive DC connectors of input B.