11  Troubleshooting

SMA Solar Technology AG

64

WB3-5TL-21-IA-en-10

Installation Manual

1501

Reconnection fault grid

The changed country data set or the value of a parameter
you have set does not correspond to the local
requirements. The inverter cannot connect to the power
distribution grid.
Corrective measures:

• Ensure that the country data set has been

configured correctly. Check the setting of the rotary
switches A and B or select the parameter
Set country standard or CntrySet and check the
value.

3301 to
3303

Unstable operation

The supply at the DC input is not sufficient for stable
operation. The inverter cannot connect to the power
distribution grid.
Corrective measures:

• Ensure that the small wind turbine system is

correctly rated.

3304

Gen. output too low

The small wind turbine system delivers insufficient DC
power. The inverter cannot connect to the power
distribution grid.
Corrective measures:

• Wait for stronger wind, if necessary reduce the

critical voltage to start feed-in. To do this, change
the parameter Critical voltage to start feed-in or
A.VStr.

• If this message is frequently displayed at medium

wind conditions, ensure that the small wind turbine
system is correctly rated.

Event
number

Display message

Cause and corrective measures