MP2000 Quick Reference Guide Rev1.21

Function Block Specification / Reserved Data Area Access  3/4

-

Run Command-2

MW30242

OW8004

-

Run Status-2

MW30201

IW800C

RDA#

Datas Name

M-Register

-

Run Status-1

MW30200

Remarks

-

Warning

ML30214

IL8002 - Warning

-

MW30217

Latched Position

Detail

- Position Status

(IWC000)

MW30203

-

IL8004

IL8040 - Feedback Speed Monitor

- Latch Signal Selection

(OWC000)

OW8000
OW8003

-

ML30244

-

Run Command-3

MW30243

OW8005

Position Offset

ML30254

-

Speed Reference

ML30250

(OLC006)

-

Ext. Travel Distance

ML30256

OL8046

(OLC024)

-

ML30262

OL803E

- Approch Speed

- External travel distance for latch target

MW30260

- Motion Command Control Bits

OW8008

- Motion Command Code

-

Creap Speed

ML30264

OL8040

- Creap Speed

-

Approch Speed

-

Zrn. Travel Distance

- Zrn travel distance

ML30266

OL8042

OW803C

- Zero point return method

-

Accel Time

ML30246

-

ZRN Mode

MW30261

-

Servo Alarm Code

MW30216

IW802D - Servo Alarm Code

(IWC024)

-

Servo DI Monitor

-

Servo Status

MW30202

IW8000 - Run Status

(IWC000)

IW802C

IL8018 - Latched Position

-

Target Position

ML30204

IL8010 - Target Position

(ILC002)

-

-

Command Status

MW30210

-

Actual Position

ML30208

ML30206

-

Command Response

MW30211

-

Alarms

ML30212

-

Speed Ref. Monitor

ML30218

IW8008 - Motion Command Response

(IWC014)

IL8020 - Speed Reference Monitor

(ILC026)

IW802E - Servo DI Monitor

(IWC025)

- Servo Status

(IWC001)

- Alarm

(ILC022)

(ILC006)

(ILC002)

- Acutal Position

(ILC008)

IW8009 - Motion Command Status

(IWC015)

IL8016

-

Feedback Speed

ML30220

-

Run Mode

MW30240

- Run Mode

-

Run Command-1

MW30241

(OWC00D)

-

Decel Time

ML30248

-

Position Reference

ML30252

-

Filter Time

MW30258

OW803A

-

Motion Command Code

MW30259

OW8009

-

Motion Command Bits

(OWC021)

OL8038

- Deceleration time

(OWC020)

(OWC014)

- Filter Time

(OLC012)

- Speed Reference

OL8010

- Filter, User Unit

- Zero point return INPUT Siganal

(OLC022)

(OWC00C)

OL8048

- Position Offset

-

OL801C

- Position Reference

OL8036

- Acceleration time

1204

ML30288

Buf1 -Absolute Position at Power OFF (Lower 2word)

1200

Buf0 Abs Pos -L

ML30280

1205

ML30290

Buf1 -Absolute Position at Power OFF (Upper 2word)

Buf1 Abs Pos -U

Buf1 Abs Pos -L

1207

Buf1 Mod Pos -U

ML30294

Buf1 -Modularized Position at Power OFF (Upper 2word)

1206

Buf1 Mod Pos -L

ML30292

Buf1 -Modularized Position at Power OFF (Lower 2word)

Buf0 -Absolute Position at Power OFF (Lower 2word)

1201

Buf0 Abs Pos -U

ML30282

Buf0 -Absolute Position at Power OFF (Upper 2word)

1203

Buf0 Mod Pos -U

ML30286

Buf0 -Modularized Position at Power OFF (Upper 2word)

1202

Buf0 Mod Pos -L

ML30284

Buf0 -Modularized Position at Power OFF (Lower 2word)

Page 19 of 25