Appendix A - Optional Equipment and Accessories

Info: Make sure enough insulation is stripped so that the inverter’s AC input wire is
fully inserted in the AC terminal block and enough uninsulated wire is still available
to contact with the lightning arrestor wire, when using a service entrance connector.

Info: Some readily used service entrance connectors are the Type SX manufactured
by Ilsco (

www.ilsco.com

), or the Type N manufactured by Thomas and Betts (

www.

tnb.com

).

N

OTE

: C

RIMP

A

RING

TERMINAL

WITH

A

5/16"

OPENING

TO

THE

LIGHTNING

ARRESTOR

WIRES

AND

THEN

CONNECT

TO

THE

M

AGNUM

INVERTER

S

DC

TERMINALS

. F

OLLOW

THE

PROPER

DC

HARDWARE

STACK

AND

ENSURE

THERE

IS

NOTHING

BETWEEN

THE

DC

CABLES

AND

THE

INVERTER

S

DC

TERMINALS

.

Lightning

Arrestor

(DC rated)

T

O

P

ROTECT

I

NVERTER

S

DC

INPUT

T

O

P

ROTECT

I

NVERTER

S

AC

INPUT

SIDE VIEW

of an AC input

circuit

breaker

S

ERVICE

E

NTRANCE

C

ONNECTOR

(

SPLIT

BOLT

)

I

NVERTER

AC

INPUT

W

IRE

L

IGHTNING

A

RRESTOR

W

IRE

N

OTE

: T

HE

AC I

NPUT

C

IRCUIT

B

REAKER

(

S

)

ARE

NOT

RATED

TO

CONNECT

MORE

THAN

ONE

WIRE

.

T

HEREFORE

,

TO

CONNECT

A

LIGHTNING

ARRESTOR

TO

THE

AC

CIRCUIT

BREAKER

,

A

SERVICE

ENTRANCE

CONNECTOR

(

OR

SPLIT

BOLT

)

IS

REQUIRED

TO

CONNECT

BOTH

THE

INVERTER

S

AC

INPUT

WIRE

AND

THE

LIGHTNING

ARRESTOR

WIRE

.

E

NSURE

THE

SERVICE

ENTRANCE

CONNECTORS

ARE

INSULATED

FROM

EACH

OTHER

TO

PREVENT

THEM

FROM

SHORTING

TO

EACH

OTHER

.

Lightning

Arrestor

(AC rated)

Lightning

Arrestor

(DC rated)

T

O

P

ROTECT

I

NPUT

TO

DC

LOADS

Figure A10-2, Wiring Lightning Arrestor to MP Enclosure