2.0 Introduction

2.3 MP External Components

The main external components of the MPSL and MPSH enclosures (as shown in Figure 2-5) and
the MPDH enclosure (as shown in Figure 2-6) are described below:

Info: The external components are secured to the enclosure using #10-32 x 3/8” (Pan
head, T25 Torx drive) thread cutting screws and #10 lock washers.

1

Inverter Plate - The MP enclosure is factory shipped with the inverter plate installed.
This plate allows a Magnum inverter to sit on top of the MP enclosure, and allow the AC
and DC wiring to be easily routed from the inverter to the MP enclosure.

The inverter plate can be replaced with the Knockout Plate, which is used as an upper
conduit/safety plate. See Section A5 for more information on the Knockout Plate.

WARNING: To prevent accidental access to live electrical circuits inside the
MP enclosure, the Knockout Plate must be installed if the Magnum inverter is
removed for service and the AC bypass breaker is switched ON.