World class 3000, Instruction manual – Emerson Process Management 3000 User Manual

Page 37

Advertising
background image

Instruction Manual

IB-106-300NH Rev. 4.2

July 2002

Rosemount Analytical Inc. A Division of Emerson Process Management

Installation 2-5

World Class 3000

NOTE: ALL MASONRY STACK WORK AND JOINTS EXCEPT

ADAPTOR PLATE NOT FURNISHED BY ROSEMOUNT.

INSTALLATION FOR MASONRY

WALL STACK CONSTRUCTION

INSTALLATION FOR METAL

WALL STACK OR DUCT

CONSTRUCTION

0.50 [13]

3.75 [95]

MIN DIA HOLE

IN WALL

STACK OR DUCT

METAL WALL

MTG HOLES

SHOWN ROTATED

45 OUT OF

TRUE POSITION

o

WELD OR BOLT ADAPTOR

PLATE TO METAL WALL

OF STACK OR DUCT.

JOINT MUST BE AIR TIGHT.

0.50 [13]

4.50 [114]

O.D. REF

PIPE 4.00 SCHED 40

PIPE SLEEVE (NOT

BY ROSEMOUNT)

LENGTH BY CUSTOMER

MASONRY

STACK WALL

OUTSIDE WALL

SURFACE

JOINT MUST

BE AIRTIGHT

MTG HOLES

SHOWN ROTATED

45 OUT OF

TRUE POSITION

o

FIELD WELD

PIPE TO

ADAPTOR PLATE

BOLT ADAPTOR

PLATE TO OUTSIDE

WALL SURFACE

NOTE: DIMENSIONS IN INCHES WITH

MILLIMETERS IN PARENTHESES.

2.50 [63.5]

MIN DIA HOLE

IN WALL

STACK OR DUCT

METAL WALL

WELD OR BOLT ADAPTOR

PLATE TO METAL WALL

OF STACK OR DUCT.

JOINT MUST BE AIR TIGHT.

FIELD WELD

PIPE TO

ADAPTOR PLATE

3.50 [89]

O.D. REF

PIPE 3.00 SCHED 40

PIPE SLEEVE (NOT

BY ROSEMOUNT)

LENGTH BY CUSTOMER

MASONRY

STACK WALL

OUTSIDE WALL

SURFACE

JOINT MUST

BE AIRTIGHT

BOLT ADAPTOR

PLATE TO OUTSIDE

WALL SURFACE

624038

Figure 2-1. Probe Installation (Sheet 4 of 5)

2

Advertising