TELEPHONE INTERFACE MODULE (TIM)

14-11

14.5 TIM SETUP PROCEDURE

There are two personality cards that may be setup

and aligned: (See Figures 14-19, 14-20 and 14-21.)

1. 2WY (new style) Section 14.6.

Part No. 023-3039-670
Reg. # ATHUSA-61094-MF-E

2. DID Section 14.8.

Part No. 023-3039-660
Reg. # ATHUSA-61904-MF-E

3. 4-Wire E&M Section 14.10

Part No. 023-3039-680

14.5.1 TIM JUMPER PLACEMENT

14.5.2 MAIN BOARD SWITCH SETTINGS

The TIM does not use secondary signaling for

Command and Control Communication (see Figure
14-18).

14.6 2WY SETUP AND ALIGNMENT

PROCEDURES (-670)

2WY card (023-3039-670) is to be setup and

aligned according to the following procedures. The
023-3039-670 has been approved with the following
FCC number ATHUSA-61094-MF-E.

14.6.1 2WY JUMPER SETUP

14.6.2 2WY PRE-ALIGNMENT PROCEDURES

The Central Office (CO) typically provides a dial

up Test Tone (TT) and a Silent Line (SL). A DDO or
2WY TIM can dial these numbers for alignment
purposes when the modules are installed in a working
system.

The TT from the CO is typically the maximum

level the line will output or accept. The typical level
is 0 dBm at the CO interface. The average level of
speech on the line will typically be -13 to -16 dBm.

Table 14-3 TIM JUMPER PLACEMENT

JU

Pin

Description

J24

1 to 2*

2 to 3

Selects 27512 EPROM operation
Selects 27256 EPROM operation

J27

1 to 2

2 to 3*

Not used
Normal operation

P33

1 to 2
3 to 4

5and 6

open
open
open

J36

1 only

1 to 2
2 to 3

Not used
-48V E-lead operation
-15V E-lead operation

J14
J15
J21
J22

Jumper pin 1 to 2 for high impedance ground path
for split 600 ohm inputs and outputs. Leave open if
no ground path desired.

* Indicates normal operation.

Table 14-4 TIM SWITCH SETTINGS

Switch

Open Sections

Close Sections

S1
S3
S4
S5

1
1
1

-

2
2
2

-

-

3
3

-

4
4
4

-

-
-
-

1

-
-
-

2

3

-
-

3

-
-
-

4

Table 14-5 2WY JUMPER PLACEMENT

JU

Pin

Description

J204

1 to 2
2 to 3
2 only*

Loop Impedance
High impedance < 19k ohms
Low impedance < 150 ohms
Infinite impedance

J205

1 only*
1 to 2

Line default disable mode - RING
Open line
Default to ground

J206

1 only*
1 to 2

Line default disable mode - TIP
Open line
Default to ground

J207
J208

Battery or Ground Detect - TIP

J207
1 only
1 to 2*
2 to 3
1 to 2
2 to 3

J208
1 to 2
1 to 2*
1 to 2
2 to 3
2 to 3

No detect
-12V or less
-7V or less
Not Used
-5V or more

J209

1 to 2
1 only*

Transmit Gain
No gain
+6 dB gain

2WY Ground Start - Tip P1, pin 32,
Ring P1, pin 31