Section 10 dispatch channel module (dcm), 1 description, 1 repeater signaling – EFJohnson 3000 SERIES User Manual

Page 89: 2 repeater control, 3 voice connection, 4 internal communication, 2 dcm setup procedure, 1 dcm switch settings, 2 afsk communication on the main lines, 3 dcm jumper placement

Advertising
background image

10-1

DISPATCH CHANNEL MODULE (DCM)

SECTION 10 DISPATCH CHANNEL MODULE (DCM)

10.1 DESCRIPTION

Refer to 3000 Series Switch Service Information

manual, Part No. 001-3139-102, for the component
layout, parts list and schematic. Refer to Figure 7-1 for
the Basic Board block diagram. The Dispatch Channel
Module (DCM) connects the Switch to a Conventional
Repeater. Each repeater has a DCM that controls the
repeater through logic signaling.

10.1.1 REPEATER SIGNALING

The DCM exchanges control information with the

CRM via Audio Frequency Shift Keying (AFSK) data
in a blank and burst mode on the voice audio path.

10.1.2 REPEATER CONTROL

The DCM monitors and controls the repeater

transmit, receives confirmation of all requests made to
the repeater and sends information the repeater
received.

10.1.3 VOICE CONNECTION

The DCM provides a 4-Wire 600 ohm balanced

voice connection to the repeater, converts audio to and
from Pulse Code Modulation (PCM), transmits and
receives on the PCM buses, and controls voice audio
gating to and from the repeater.

10.1.4 INTERNAL COMMUNICATION

The DCM uses the Intra-Terminal Data Bus

(IDB) to communicate to other modules and send
messages to and receive messages from the Call
Processor that controls its actions.

The DCM monitors the CSB to determine if a

CIM is active with the appropriate group.

10.2 DCM SETUP PROCEDURE

10.2.1 DCM SWITCH SETTINGS

Refer to Figure 10-1 for the Alignment Points

Diagram.

Command and Control Communication

The command and control communication to the

Conventional Repeater Module (CRM) is by blank and
burst mode of Audio Frequency Shift Keyed data on
the Main audio lines.

10.2.2 AFSK COMMUNICATION ON THE MAIN

LINES

Refer to Table 10-1 for switch settings.

10.2.3 DCM JUMPER PLACEMENT

Table 10-1 DCM SWITCH SETTINGS

Switch

Open Sections

Close Sections

S1
S3
S4
S5

1
1
1

-

-

2
2

-

-

3
3

-

4
4
4

-

-
-
-

1

2

-
-

2

3

-
-

3

-
-
-

4

Table 10-2 DCM JUMPER PLACEMENT

JU

Pin

Description

J24

1 to 2*
2 to 3

Selects 27512 EPROM operation
Selects 27256 EPROM operation

J27

1 to 2
2 to 3*

Not used
Normal operation

P33

1 to 2
3 to 4
5 and 6

open
open
open

J36

1 only
1 to 2
2 to 3

Not used
-48V E-lead operation
-15V E-lead operation

J14
J15
J21
J22

Jumper pin 1 to 2 for high impedance ground path
for split 600 ohm inputs and outputs. Leave open if
no ground path desired.

* Indicates normal operation.

Advertising