SYSTEM RACK

4-16

Processor’s Device Activity window. If neces-
sary, press the reset button S1on the NetNim to
activate the clock status.)

PCM Bank Verification

PCM Bank Verification requires two Channel

Interface Modules (CIMs).

1. On both CIMs place a patch cord from the top jack

of J1 to the top jack of J2 (see Figure 10-1).

2. Close S1, sections 3-4; open sections 1-2 on each

module.

3. On both CIMs set switch sections as follows:

Switch

Section

S3

1-2 open; 3-4 closed

S4

1-2 closed; 3-4 open

S5

1-2-3-4 closed.

4. Set one module for System Test "5"

(S5-sections 1 and 3 open; sections 2 and 4 closed).
Place this module in any slot on Shelf 1.

5. Set the second module for System Test "6".

(S5-sections 2-3 open; 1-4 closed). Place this
module in any slot on Shelf 6.

6. Loop Primary Tx PCM to the Primary Rx PCM by

connecting a cable (023-3039-842) from Shelf 1-J3
to Shelf 1-J4 (see Figure 4-5).

7. The modules display an "A" if the PCM bank is

good. Press S2 to reset the module if "A" is not
displayed.

A failure on the primary displays a "1" on one or
both modules.

A failure on the secondary displays a "2" on one
or both modules.

8. Repeat this procedure by moving the module on

Shelf 6 to Shelf 5. Reset both modules if "A" is not
displayed.

9. Repeat this procedure by moving the module on

Shelf 5 to Shelf 4. Reset both modules if "A" is not
displayed.

10.Repeat this procedure by moving the module on

Shelf 4 to Shelf 3. Reset both modules if "A" is not
displayed.

11. Repeat this procedure by moving the module on

Shelf 3 to Shelf 2. Reset both modules if "A" is not
displayed.

12.After the PCM bank has proven good, force failures

on both the primary and secondary as follows:

Primary

Remove cables on Shelf 1, J5 and J6.

A "1" on both modules indicates a Primary
failure.

Reconnect the cables.

Secondary

Remove cables on Shelf 1, J23 and J24.

A "2" on both modules indicates a Secondary
failure.

Reconnect the cables.

Remove the cable from Shelf 1, J3 to J4.

13.Remove CIMs from rack and patch cords from

J1-J2.

VTM PCM Bank Verification

This requires the use of one CIM and one VTM1.

1. Verify the VTM1 card is in Shelf 1-slot 2.

2. On the VTM1 connect a Transmission Test Set to

TP1 and TP2 (common).

3. On the VTM1 set S2 to select the 1020 Hz align-

ment tone. The tone should be heard in the Test Set
speaker. Adjust the monitor volume as necessary.

4. Set the CIM for System Test "1".

(S5, section 1 open; sections 2,3,4 closed.)

5. Place the module in any slot on Shelf 1.

Advertising