TELEPHONE INTERFACE MODULE (TIM)

14-12

The TIM should be pre-aligned using the Basic

Board Module alignment procedures, Section 14-18.

Input With Personality Card Installed

1. Jumper T201, pin 8 to T202, pin 12.

2. Insert 1004 Hz at -12 dBm with a 600 ohm driving

impedance into the EQU of J1.

3. Set S5 for Test 7 ( sections 1, 2 and 3 open, close 4).

4. Reset the module, Press S2 and release.

5. Adjust R41 for -6 dBm

±

0.5 dB at J11.

6. Verify -6 dBm

±

1 dB at TP5.

7. Adjust R214 on the personality card for -12 dBm

±

1 dB at EP223 (DTMF input level).

8. Adjust R210 on the personality card for -12 dBm

±

1 dB at EP222.

9. Set S5 for normal operation (all sections closed).

10.Reset the module, Press S2 and release.

Bandpass Filter and Pulse Detector

1. Jumper T201, pin 8 to T202, pin 12.

2. Insert 395 Hz at -12 dBm with a 600 ohm driving

impedance into the EQU of J1. (The typical Dial
Tone is 380 + 440 Hz, the 395 Hz simulates this Dial
Tone.)

3. Set S5 for Test 7 (sections 1, 2 and 3 open, close 4).

4. Reset the module, Press S2 and release.

5. Verify -6 dBm

±

0.5 dB at J11.

6. Verify -6 dBm

±

1 dB at TP5.

7. Adjust R210 on the personality card for 0 dBm

±

1 dB at EP222.

8. Adjust R257 for a peak level at U203, pin 7

(typically -1 dBm

±

1 dB).

9. Set Detector

a. Measure EP225 with an oscilloscope.

b. Adjust R274 until EP225 is high ( >4V).

c. Adjust R274 until EP225 just goes low (< 0.8V).

d. Verify that EP226 is a square wave of the input

waveform.

5. Set S5 for normal operation (all sections closed).

6. Reset the module, Press S2 and release.

Output

1. Jumper T201, pin 8 to T202, pin 12.

2. Place a 600 ohm resistor in series with a non-polar-

ized 2.2

µ

F capacitor in EQU J1.

3. Set S5 for Test 1 (1 open, close 2, 3 and 4).

4. Reset the module, Press S2 and release.

5. Adjust R83 for -3 dBm

±

0.5 dB at TP3.

6. Adjust R44 to be -9 dBm

±

1 dB at J12.

(This provides a maximum level of -13 dBm

±

2 dB

across the line. The loss is due to the hybrid trans-
former. Verify the level across the 600 ohm resistor
and 2.2

µ

F cap is -13 dBm

±

2 dB, measure with a

balanced non-grounded AC voltmeter.)

7. Mobile Speech Detection

a. Set S5 for Test 7 (section 1, 2, 3; open, close 4).

b. Reset the module, Press S2 and release.

c. Insert 700 Hz into J2 EQU with a 600 ohm

balanced ungrounded oscillator.

d. Set oscillator for -15 dBm at J201, pin 5.

e. Adjust R282 for -18 dBm

±

1 dB at EP227.

f. Adjust R286 (counterclockwise) for a peak at

U220, pin 7, -19 dBm

±

1 dB.