4 alignment, Alignment – EFJohnson 3000 SERIES User Manual

Page 95

Advertising
background image

DISPATCH INTERFACE MODULE (DIM)

11-3

14.Main Tx Audio Output Level From J1.

a. Setup for alignment as in Step 1.

b. Adjust R83 for a -3 dBm

±

0.5 dB level at TP3.

c. Adjust R44 for a -12 dBm

±

0.5 dB level at J12.

4. Tone Remote PTT Tone Output Level.

a. Set S5 for Test 2 (open section 2, close 1, 3 and

4).

b. Reset the module, Press S2 and release.

c. Adjust R267 for +8 dBm

±

0.5 dB at EP226.

d. Verify the level at J12 to be -1 dBm

±

1 dB.

5. DTMF Encoder Level of the Tone Remote Card.

a. Set S5 for Test 3 (open sections 1 and 2, close 3

and 4).

b. Reset the module, Press S2 and release.

c. Adjust R216 for -3 dBm

±

0.5 dB at EP223.

d. Verify the level at J12 to be -12 dBm

±

1 dB.

5. Normal Operation

a. Set S5 to 0, normal operation (sections 1, 2, 3 and

4 closed).

b. Reset the module, Press S2 and release.

c. Remove the input alignment tone from J1.

NOTE: FSK is not aligned since it is not used on the
DIM.

11.4 ALIGNMENT

Connections to the DIM may take several forms:

1. Direct Connection.

2. Leased Lines.

3. Microwave Link.

4. T1 Channel Bank Interfaces.

This ancillary equipment requires certain input

and output levels for proper operation. The module
should be adjusted accordingly.

Main Transmit

1. Determine the maximum level to be received by the

ancillary equipment to be transmitted.

2. Set S5 to Test 1 (open section 1, close sections 2, 3

and 4)

3. Reset the module, Press S2 and release.

4. Adjust R44 for -12 dB from the maximum level in

Step 1 at J12.

5. Set S5 for normal operation (all sections closed).

6. Reset the module, Press S2 and release.

Example: Microwave has -16 dBm max input, set
J12 for -28 dBm.

Main Receive

1. Determine the maximum transmit level that is sent

by the ancillary equipment to the interface module.

2. Set S5 to Test 1 (open section 1, close sections 2, 3

and 4).

3. Reset the module, Press S2 and release.

4. Insert the maximum level determined in Step 1

using a 600 ohm audio oscillator into EQU port of
J1. Otherwise, set the ancillary equipment to send
the alignment tone to the interface module.

5. Adjust R41 to be -6 dBm at J11.

6. Set S5 for normal operation (all sections closed).

7. Reset the module, press S2 and release.

Example: Microwave has +7 dBm maximum
output, set J11 for -5 dBm.

Advertising