5 voltage adjustments, 6 redundant supply adjustments, 7 verify fan air flow direction – EFJohnson 3000 SERIES User Manual

Page 34: 8 verify voltages on power distribution cable, Power supply connections -8

Advertising
background image

SYSTEM RACK

4-8

4.2.5 VOLTAGE ADJUSTMENTS

See Figure 4-10 for location of components and

Table 4-2 for wire connections.

1. Connect a voltmeter to U1, pin 76 on an RVM (DO

NOT use an extender card).

2. Adjust the +5V pot on the power supply for a

reading of 5.1V.

3. If +5.1V cannot be obtained, change R84 to a 5.6k

ohm 1/4W resistor.

4.2.6 REDUNDANT SUPPLY ADJUSTMENTS

See Figure 4-10 for location of components and

Table 4-2 for wire connections.

1. Remove the AC voltage to one of the supplies.

2. Connect a voltmeter to U1, pin 76 on an RVM (DO

NOT use an extender card).

3. Adjust the +5V pot for a reading of 5.1V. (If +5.1V

cannot be obtained, change R84 to a 5.1k ohm 1/4W
resistor.)

4. Connect a voltmeter to output of CR3 and verify that

the -5V line is -4.8V to -5.2V. (If not, make R68
lower to raise voltage.)

5. Remove the AC voltage to the adjusted supply and

connect AC voltage to the other power supply.

6. Connect a voltmeter to U1, pin 76 on an RVM (DO

NOT use an extender card).

7. Adjust the +5V pot for a reading of 5.1V. (If +5.1V

cannot be obtained, change R84 to a 5.1k ohm 1/4W
resistor.)

8. Connect a voltmeter to output of CR3 and verify that

the -5V line is -4.8V to -5.2V. (If not, make R68
lower to raise voltage.)

4.2.7 VERIFY FAN AIR FLOW DIRECTION

1. Connect the power cables to a 110V AC source.

2. Connect the Plus lead of the Fan Cable to Bus Bar

D1-16.

3. Verify both power supplies are turned OFF.

(Power Supply "A", is located on the left side at the
bottom of the rack. Power Supply "B" is located on
the right side at the bottom of the rack.)

4. Install both power supplies.

5. Turn Power Supply "A" on.

6. Verify that the Power On indicator is "ON" for

Power Supply "A".

7. Verify that the air flow from the fan is to the outside.

4.2.8 VERIFY VOLTAGES ON POWER DISTRI-

BUTION CABLE

1. Verify voltages in Table 4-13 for the Power Termi-

nation Cables for Shelves 1-6.

2. Turn Power Supply “A” OFF.

Table 4-7 POWER SUPPLY CONNECTIONS

TB1

Wire

No.

Color

From

Term 1
Term 2
Term 3

W1
W1
W1

Blk
Wht
Grn

AC (Hot)
AC (Ntrl)
AC (Gnd)

Line
Line
Line

TB2

Term 1
Term 2
Term 3
Term 4
Term 5
Term 6
Term 7
Term 8
Term 9

W1
W2
W6
NC
W7
W4
W5
W3
W8

Red
Red
Blu

Blu
Blu
Wht
Grn
Blu

+5V
+5V
Gnd

Gnd
+12V
-12V
-5V
Gnd

F1
F1
Gnd

Gnd
F3
F4
F2
Gnd

Advertising