3 switch settings on 6132a (did applications), Switch settings on 6132a (did, Applications) -24 – EFJohnson 3000 SERIES User Manual

Page 134: 23 tellabs 6132a - did -24, 10 tellabs 6132a - did -24

Advertising
background image

TELEPHONE INTERFACE MODULE (TIM)

14-24

14.11.3 SWITCH SETTINGS ON 6132A (DID AP-

PLICATIONS)

Figure 14-23 TELLABS 6132A - DID

Table 14-10 TELLABS 6132A - DID

Sw

Purpose

S14 Initially set to NORM. If the E-Lead (Green LED)

stays on constantly, or the termset does not answer
in-dial, place S14 in REV position. This switch
reverses the battery polarity presented to the CO
from the Termset in DID applications.

S5

Place in 2W. This switch determines the interface.

S4

To get started, set to 900, with all capacitors in. Set
to variable and adjust R38 when performing the
actual balance. This balance network allows 600,
900 or variable resistor (2k) resistive balance. Also,
5 capacitors ranging from .002

µ

F to .032

µ

F in

octaves (i.e. .064

µ

F total capacitance) provide for a

capacitive balance.

R38 This potentiometer controls the resistive balance in

the variable mode of S4.

S11 Set to B. This switch swaps roles of E-Lead and M-

Lead.

S12 Supervisory Mode. Set to RB (Reverse Battery) for

DID applications.

S15 Set to a = inv, b = inv, c = d = e = off.

'a' sets up inverted E&M inputs.
'b' sets up inverted E&M outputs.
'c' sets up continuous (vs. interrupted ringing.
'd' sets up no ring-back tone.
'e' sets up no pulse correction.

S3

Set to 600. This switch provides 2W port terminat-
ing impedance.

c = d = e = off

b = inv

a = inv

S15

RB (REVERSE BURST)

B

S11

BOTTOM UP

600

S3

S12

TOP DOWN

R38

ALL CAPS ON

900

S4

2W

S5

NORM

S14

Advertising