Epson Action Laser II User Manual

Page 105

Advertising
background image

Using the SUB CONFIG Option

FORM TOP

0.50

0.50-1.50 (inch)

This option specifies

the

distance from the top of the

sheet to the

baseline of

the

first printable line. This is measured in 0.05-inch

increments. The factory setting is 0.50 inches.

TEXT

66LINES

1 to available

Use this option to set the page length. The unit of measure for this

option is 1/6th of

an

inch. If you change the ORIENT, P-SIZE, or

FORM TOP settings with SelecType, the form length setting

automatically returns to the default setting for each paper size. The

factory

setting

is 62 (line spacing 6 lines per inch).

SKIPBOTTOM

OFF

*OFF

ON

When SKIPBOTTOM is set to on, the printer inserts the number of

line spaces specified by the ESC N (skip-over-perforation) command

between the last line printed on one page and the first printable line

on

the next

page. The total number of lines skipped equals the

FORM TOP setting plus the amount of skip-over-perforation set

with ESC N. Since most application programs insert their own top

and bottom margins, you should use this feature only if your

program does not provide them.

SelecType

4-41