Theoretical notions for installation

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

2.5.1. Examples of flue pipes














Square or rectangular section flue pipes must have rounded internal

corners with radius not less than 20mm. For the rectangular section,

the ratio between internal dimensions must be ≤1.5.
The sections/lengths of the flue pipe shown in the technical data table

are guidelines for correct installation. Any alternative configurations

must be suitably sized in accordance with EN13384-1.
The smoke duct should be equipped with a solid material collection

chamber at the mouth of the smoke duct to be easily opened with an

airtight door.

IMPORTANT !

In the event of doubt on your chimney flue operations or

that its dimensions are different from those recommended,

we highly suggest an authorised MCZ technician inspect and

measure

chimney

flue

performance

(micro-gauge

measurements)
MCZ s.p.a. shall not be held liable for poor operation of the
fireplace stove that is due to a flue pipe of improper size or

installation that does not comply with provided

requirements.




AISI 316 stainless steel
flue

pipe

with

dual

chamber insulated with
ceramic wool or equivalent
resistant to 400°C.
EXCELLENT

Flue pipe in refractory brick
with insulated double wall and
external coat of cement mix
lightened with honeycomb
material such as clay.
GOOD

Traditional square section
clay flue pipe with insulating
hollow inserts.
GOOD

Avoid flue pipes with internal
rectangular

sections

whose

larger side is double the smaller
such as 20x40 or 15x30.
AVERAGE