Safety function, Light on (if present), Replacing the fuse of the control unit – MCZ Forma Wood 115 User Manual

Page 34: On off

Advertising
background image

INSTALLATION AND USE MANUAL

Chapter 5

page

34

Comfort air kit

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

MANUAL

mode (MAN LEDon 4b)

The fan runs at the selected speed independently of the

temperature measured by the sensor. When the stove unit is

turned on, on the control unit place selector 4 in manual 4b.
The speed of the fan is set using the knob (3).
With the knob turned completely to the left, the fan is off as is

the indicator light (1). Turn the knob to the right to change
from “OFF” to “ON” (indicator light 1 on).

  If you continue

turning the knob to the right, the speed of the fan will gradually

increase (indicator light 2 on).
In manual mode, the fan will operate in a mode regardless of
the probe, and will therefore be controlled by the knob (3)

5.5.3.

Safety function

When knob 3 is in the off position, the safety function is active.
If the temperature probe reaches the safety threshold, the fans

come on at minimum speed to prevent overheating of the

structure.
If the safety function trips frequently, contact the technical service

department of MCZ.

5.5.4.

Light on (if present)

Press button 5 to turn the light on or off.
The LED 5a indicates the status of the light.

5.5.5.

Replacing the fuse of the control unit

The control unit is equipped with a fuse that protects the system

against voltage overloads.
When mains power is provided at 230V-50Hz, if none of the indicator

lights of the control unit come on, the fuse is probably faulty.
To replace it, proceed as follows:

remove the plate that covers the control unit

unscrew the two screws that hold the control unit to the wall
box

carefully extract the body of the control unit

open the plug and replace the faulty fuse with a working one

(about 1 A)

IMPORTANT!
All electrical connections must be performed by

qualified personnel in accordance with current laws in

each nation, using suitable equipment and in

compliance with the diagram indicated in this booklet.

All operations must be performed with the 230V 50 Hz

mains power cord disconnected.
Mcz shall not be held liable for damage to persons or

things due to incorrect connections or improper use of

the device.

ON

OFF

Advertising
This manual is related to the following products: