General information on the control unit, On/off, Operation – MCZ Forma Wood 115 User Manual

Page 33

Advertising
background image

INSTALLATION AND USE MANUAL

Chapter 5

page

33

Comfort air kit

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

2

3

4

4a

5a

4b

1

5

5.5. GENERAL INFORMATION ON THE CONTROL UNIT












1. “ON” –“OFF” indicator light
2. Fan active light
3. Fan speed control knob
4. MAN/AUT button

4a. Automatic
4b. Manual

5. Lamp on button

5a. Lamp on/off


The device makes it possible to control the speed of the fan it is
connected to.

  The speed is set by turning the knob to 10 speed steps:

0 ,V1; ….. V9, V10.
MANUAL/AUTOMATIC

  mode is set using button 4.

5.5.1.

On/off

The control unit is turned on and off by turning knob 3.
On status is indicated by LED 1.

5.5.2.

Operation

Activation of the fan is signalled by LED 2

AUTOMATIC mode (AUT LED

on 4a)

The AUT is generally used to turn off the fan.
For example, in the evening you can load wood for the last time

and turn the selector to AUT. The fan, with the consent of the

probe, will continue to provide hot air until the temperature

drops. In this way, you will keep the room comfortable all night

long. The next morning, the fire box will contain embers ready

for a new load of wood or it will be out.


Advertising
This manual is related to the following products: