External and internal air intake, Combustion air inlet, Air inlet for natural ventilation – MCZ Forma Wood 115 User Manual

Page 23: Air inlet for forced ventilation, Ducts for kit comfort air, Air inlet for forced ventilation 4.6.3.1

Advertising
background image

INSTALLATION AND USE MANUAL

Chapter 4

page

23

Installation and assembly

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

4.6. EXTERNAL AND INTERNAL AIR INTAKE

4.6.1. Combustion air inlet

The FORMA fireplace stove is set up with two side holes Ø 100 mm,

already opened, for the entry of air required for combustion.
Connect by flanges ø100 and hose at least one of the combustion air

inlets (fig. 4) grilles inside or outside the room of installation so that the

path is separate from the air of natural or forced convection.

NEVER CLOSE OFF THE COMBUSTION AIR INTAKE

HOLES.
WHEN INSTALLING THE CLADDING, MAKE SURE

THAT NONE OF ITS PARTS OBSTRUCT THE AIR

INTAKES

CONNECT AT LEAST ONE OF THE TWO DUCTS AND

ALWAYS RUN IT OUTSIDE THE CLADDING OF THE

FIREPLACE STOVE. IF YOU DO NOT COMPLY WITH

THIS RULE, THE COMFORT AIR KIT MAY DRAW IN

THE AIR INTENDED FOR COMBUSTION

4.6.2. Air inlet for natural ventilation

If the fireplace stove is installed with natural ventilation, i.e. with no

electric fan, make an external combustion air intake of 300 cm² net

behind the unit so that fresh air always flows beneath the fireplace

stove.

(figure 5)

You must comply with this instruction fully, because otherwise a lack of

oxygen may compromise combustion and calorific energy of the

product.

4.6.3. Air inlet for forced ventilation

4.6.3.1.

Ducts for kit COMFORT AIR


If the fireplace stove is installed with forced ventilation, i.e. using the
Comfort Air kit, place air intakes and ducts as follows:

for proper air circulation in the room, it is advisable to arrange one

external air intake A of 150 cm², in order to draw in clean, fresh

air; place the other B in the room where the fireplace stove is

installed (also of 150 cm²).
This mode allows a proper mix of the air in the room of installation

and better cooling of the structure of the fireplace stove.

(Figure 6)

If you cannot make this kind of connection, you will still need to arrange

both air intakes, whether they are both directed to the exterior or the

interior. Depending on the selection, you will have operating

temperatures that are slightly above or below average but which do not

compromise proper operation of the product.

Figure 5 – Intake for external combustion air
and for natural ventilation

Figure 6 – Air intakes for ducts of fan and
combustion air intake.

Air intake of 300 cm

2

for

combustion air and natural

convection

Internal and external air

intakes of 150 cm

2

for

forced ventilation air.

Combustion air intake of

150 cm

2

Figure 4 – Combustion air intakes.

A

B