Variation for air outlet with container

The essence container (2) is available only on the one-direction air

outlet with and without light. Its purpose is to humidify the air.
The container (2) can easily be removed from its seat. To do so, lift the

door (1) at the bottom and extract the container (see fig.4).
Place only water in the container.

  It is possible to add essences to

perfume the room.

IMPORTANT!
EXTRACT THE CONTAINER FROM ITS SEAT FOR

FILLING ONLY WHEN THE AIR OUTLET IS COOL AND
THE STOVE UNIT IS OFF.

5.3.2.

Variation for air outlet with illumination

If you decide to install the ventilation kit with illumination, you must

remove the knockout panel located on the structure of the air outlet

(fig.5) and pre-install the light (a).
To open the pre-cut knockout panel, strike it with a rubber mallet.

(fig.5).
Install the light (a) on the structure of the air outlet at the knockout

panel so that it is facing the front of the structure (fig. 6). Fasten the

light using the two brackets (c) with the screws (b) and bolts (d)

provided.
Once you have inserted the light (a), make the electrical connections.

In the rear part, insert the two female terminals on the tips of the light

(fig.7)
For forced ventilation, you will need to connect the power cord of the

light (included) to the control unit in the appropriate terminal. For

natural ventilation, the connection must be made to a wall switch (to

be done by the installer).
The cable provided for connection of the light is 2.5 metres.

  For

greater lengths you will need to use an extension cord.

IMPORTANT!
The cable for the connection of the light/fan is made of

silicone material to withstand high temperatures. If

you use extension cords (over 2.5 m) or in any other

circumstance, make sure that the cord does not come

into contact with the hot parts of the stove and of the

air connection hoses in the cladding of the structure.
If you install the comfort air kit with illumination, it is

necessary to pre-install the light on the kit before

inserting it in the hole.

Figure 5– Knockout for insertion of light

Figure 7-Lamp electrical connections

Figure 6– Fastening the light

Figure 4– Container