Cowl – MCZ Forma Wood 115 User Manual

Page 11

Advertising
background image

INSTALLATION AND USE MANUAL

Chapter 2

page

11

Theoretical notions for installation

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

2.6. COWL

If underestimated, it is a severe impediment to correct "chimney

system" operations.
Flue pipe draught also depends on its cowl.
Therefore, if hand made, its four exhaust sections must correspond to

more than twice the internal section of the flue pipe.
Having to exceed the peak of the roof, the cowl will be exposed

to wind, therefore an industrial type is recommended.











The cowl must meet the following requisites:

It must have an internal section equal to that of the chimney.

It must have a useful output section not less that double that

of the internal section of the flue pipe.

It must be built to prevent rain, snow and any foreign objects

from getting into the flue pipe.

They must be installed to guarantee adequate smoke

dispersion and out of the reflux area where negative pressure

forms.

For paired flue pipes, the cowl for solid combustion

and the one for the upper floor must be at least 50cm

higher than the other to avoid pressure transfers
between paired flues.
The cowl must not have obstacles within 10 m such as

walls, roof slopes and trees. Otherwise, raise it at least

1 m over the obstacle and, in the event of other nearby

cowls, keep them at least 2 m away. In any case, the

cowl must exceed the peak of the roof by at least 1m.







An industrial cowl,
with prefabricated
sections fitting
together, allows
optimal disposal of
the flue gases.

A

traditional

handmade

cowl.

The right exhaust
section must be at
least

twice

the

internal section of
the flue pipe, 2.5
times is ideal.

Steel cowl for flue pipe
with internal smoke
deflector cone.

1

m

t

0,

5

m

t