INSTALLATION AND USE MANUAL

Chapter 5

page

32

Comfort air kit

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

5.4. CONTROL UNIT

IMPORTANT!
All electrical connections must be performed by

qualified personnel in accordance with current laws in

each nation, using suitable equipment and in

compliance with the diagram indicated in this booklet.

All operations must be performed with the 230V 50 Hz

mains power cord disconnected.
Mcz shall not be held liable for damage to persons or

things due to incorrect connections or improper use of

the device.

5.4.1.

Composition of control unit

The following material is provided with the control unit:

A. recessed box
B. Control unit, screws for fastening and power cord
C. Probe and cable clamp
D. Terminal for the common earth cable
E. Spare fuse (1.6 A)
F. Plate
G. Instructions


The control unit is equipped with 6 double terminals for the connection of:

1. Line (1-2 LINEA)
2. Fan 1 (3-4 VENTIL.)
3. Fan 2 (5-6 VENTIL.)
4. Light (7-8 AUX)
5. Switch for door opening (9-10 PORT.)
6. Probe (11-12 SONDA)

5.4.2.

Positioning of the control unit

Make a hole in the wall (about 10X7.5 cm) for the installation of the

control unit, taking into account the positioning of the probe.
In this hole, insert the recessed box (A) without the control unit body
(B).

  Be sure to position it in a dry place, as far as possible from

heat sources, compatible with the position of the probe.
Run the cables (probe, power supply, fan and switch for door opening)

through the recessed box (A) so that they are available for connection.

Connect them to the terminals located on the control unit as shown in

figure 4.14.
Once connections are complete, insert the control unit body and fasten

it with the provided screws to the recessed box (A).
Finally, insert the white plate provided (F) or any other one, since the

control unit body is set up to house AVE SYSTEM 45 series and VIMAR

IDEA series plates using special hooks.