Precision Digital PD6060 User Manual

Page 68

Advertising
background image

Model PD6060 Dual-Input Process Meter

Instruction Manual

68

Display Parameter Action/Setting

dianmr

Diameter

Enter the tank’s diameter in inches

Length

Length

Enter the tank’s length in inches

nmath

Math

Enter the setup menu for channel C math
functions

Sunm

Sum

Channel C = (A+B+P)*F

Dif

Difference

Channel C = (A-B+P)*F

difabs

Absolute
difference

Channel C = ((Absolute value of (A-B))+P)*F

Avg

Average

Channel C = (((A+B)/2)+P)*F

nmulti

Multiplication

Channel C = ((A*B)+P)*F

Divide

Divide

Channel C = ((A/B)+P)*F

Hi-ab

Max of A or B

C = ((High value of channel A or B)+P)*F

Lo-ab

Min of A or B

C = ((Low value of channel A or B)+P)*F

Drauw

Draw

Channel C = ((A/B)-1)*F

uwAvg

Weighted
average

Channel C = ((B-A)*F)+A

ratio

Ratio

Channel C = (A/B)*F

Concen

Concentration

Channel C = (A/(A+B))*F

Const

Constant

Constant used in channel C math

adder

Adder

Addition constant used in channel C math
calculations

factor

Factor

Multiplication constant used in channel C
math calculations

CutofF

Cutoff

Set low-flow cutoff

AoutPr

Analog output
programming

Program analog output parameters

Source

Source

Select source for the 4-20 mA output

O-rang

Overrange

Program mA output for display overrange

u-rang

Underrange

Program mA output for display underrange

nmAx

Maximum

Program maximum mA output allowed

nmin

Minimum

Program minimum mA output allowed

Advertising
This manual is related to the following products: