Fig. 2 Wiring Single Contact

Fig. 3 Wiring Double Contact (on the same zone)

Wiring Passive Infra-Red Detectors

It is essential when using Passive Infra-Red Detectors that you refer to the manufacturers
instruction as to the positioning and settings of the detector. This section is intended as a
guide to the wiring of the detectors.

Fig. 4 Wiring Single PIR

P

P

P

P

a

a

a

a

g

g

g

g

e

e

e

e

5

5

5

5

Note: Both detectors must be run on a single cable

from the Control Panel to the first detector

then the second. The 2K2 resistor must be in the

last/final detector.

Zone 12V 0V

D1

D2

3K3

2K2

5K6

Alarm N/C Tamper N/C

1st Detector

2nd Detector

+ Power -

Alarm N/C Tamper N/C

+ Power -

RKP

0V

D1

Zone 12V

D2

5K6

2K2

3K3

2nd Detector

Door Contact

Alarm N/C Tamper N/C

+ Power -

RKP

Alarm

Notes
Positions of terminals will vary
according to make.

All PIR wiring diagrams apply
also to Dual Technology
Detectors and Vibration sensors.

Fig. 5 Keypad Zones (480 RKP Only)

Note: Keypad zones (480
RKP Only) are preset
and cannot be changed.
E/E - 3K3 KP Zone 1
Access - 5K6 KP Zone 2
EOL - 2K2

GardTec 480 ENG PR5832 Rev 115IN480IM B A5booklet.qxd 18/07/2007 20:35 Page 5